Transient behaviour of ITER poloidal field coils
Dublin Core
Title
Transient behaviour of ITER poloidal field coils
Subject
Technology (General)
Description
Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made using the PF 3 and PF 6 coils as examples. The calculated maximum voltages will be used for definition of amplitudes and voltage waveforms for the tests of the high-voltage insulation of the coils.
Creator
Winkler, Alexander
Source
https://www.ksp.kit.edu/9783866445956
Publisher
KIT Scientific Publishing
Date
2011
Contributor
Baihaqi
Rights
Creative Commons
Format
PDF
Language
English
Type
Textbooks
Files
Collection
Citation
Winkler, Alexander, “Transient behaviour of ITER poloidal field coils,” Open Educational Resource (OER) - USK Library, accessed October 11, 2024, http://uilis.usk.ac.id/oer/items/show/4671.